By Walt Jordan, Chief Revenue Officer, dGEN Energy Partners
Utilities are struggling to keep pace with growing electricity demand, and interconnection delays are leaving businesses waiting for power they already planned around. I recently joined Tim Montague on episode #360 of the Clean Power Hour — “The Grid Can’t Keep Up. Can Linear Generators Solve the Power Crisis?” — to talk about linear generators, and how they can work with solar, battery storage, and microgrids when the grid cannot deliver on time.
dGEN Energy Partners is a national EPC power generation company serving the U.S., Puerto Rico, and the Caribbean, with roofing, solar, linear generators, and battery energy storage (BESS).
Speed to power is now a business problem
When a facility expands, the assumption used to be that the utility could bring the additional power in time. That is no longer a given. I shared an example with Tim of a project in New York where a customer was midway through a 25-megawatt expansion when the utility said it could not deliver the additional power or a second meter. Construction was scheduled to finish around Christmas. Waiting on a grid upgrade is not a plan.
We call that constraint “speed to power.” I told Tim we were in a position to deliver what that project needed in around six months, with a best case of four or five months and a worst case of about 12 months. Behind-the-meter generation is often the path that lets a facility open on time.
Linear generators are prime power, not backup diesel
Most people default to a backup diesel unit. That is the wrong comparison. As I told Tim, “This is a prime generator meant to run full time, meant to be on 24/7 365.”
These machines run on compressible gas, including natural gas, propane, hydrogen, ammonia, methane, and biogas. They use two oscillating pistons on an air barrier system, with no spark plug and no oil, and they make power as the pistons pull apart, at about 13 beats a second. Tim noted that Mainspring, a California manufacturer he pointed listeners to, builds the units in 250-kilowatt modules, and he described visiting a northern Indiana site with me — four of those units, a megawatt of generation, paired with a flow battery.
They are not a drop-in replacement for backup power. As I explained, “It takes them about 30 seconds if you’re going to fire them up,” so “They’re not used in a backup position.” Where they do fit is continuous generation, behind the meter or at utility scale, and they can operate as grid-forming or grid-following. They do consume fuel, and the carbon outcome depends on that fuel: water if the unit runs on hydrogen, and CO2 if it runs on natural gas or methane. I also noted that the NOx levels pass California’s emission tests.
Fuel flexibility, and a fit with solar and storage
A linear generator does not have to stay on a single fuel. If a site has methane but not enough to run full time, the unit can move to natural gas on the fly — “Literally, no retooling, no changing anything.” On that same New York project, natural gas would not be on site for two years: start on trucked-in propane, then switch over when the gas line arrives, without replacing the equipment.
No single technology is a complete answer. I told Tim that solar is still going to be the cheapest power-producing product you can put on a facility, but it is limited in winter and on constrained sites. Linear generators can stand alone, or work with solar, batteries, and even a diesel unit in a backup role. “Do we have it with solar, the linear generator, battery, and a diesel backup? Again, the answer is yes.”
We have not walked away from solar. We are still navigating what I have learned to call the “solar coaster.” In the Northeast especially, solar can still pencil, even if the returns are not as aggressive as they once were. We continue to evolve our roofing and battery storage work as well, looking for the mix that delivers a real impact.
Energy still belongs in the plan from the beginning
Tim also asked how authorities having jurisdiction and fire officials respond. In my experience, once the fire marshal is comfortable with the technology, the process can move quickly. I noted that the units carry a Tier 4 Final and a UL 2200 rating, and that AHJs generally recognize them as generators.
Power has to be part of the plan from the start — the roof, solar, storage, and, where it fits, firm behind-the-meter generation — not an emergency purchase after the utility says the upgrade will not arrive in time. Linear generators will not be the right answer for every site. They require monthly maintenance, including graphite rings designed to be swapped on a 30-day interval, and they have to be applied where the load, the fuel, and the timeline make sense. But for facilities that cannot wait years for the grid, speed to power is now a competitive question.
I appreciate the opportunity to join Tim Montague and the Clean Power Hour. Watch or listen to the full conversation here:
YouTube: https://www.youtube.com/watch?v=mcWdR83AwtA
Episode page: https://cleanpowerhour.com/podcast/the-grid-cant-keep-up-can-linear-generators-solve-the-power-crisis-360/
SoundCloud: https://soundcloud.com/waltjordancro/clean-power-hour-360-the-grid
— Walt Jordan, Chief Revenue Officer, dGEN Energy Partners
dgenenergy.com