If you are weighing a commercial roof coating against a replacement, these are the questions owners ask us most. For the systems dGEN installs and how a coating project runs, start with our commercial roof coatings page. This FAQ is here to answer the buying questions in plain terms.

What is a commercial roof coating?

A commercial roof coating is a liquid applied over a sound existing roof, where it cures into a watertight, usually reflective, surface. It restores a roof that is still a good candidate. It is not a coat of paint, and it is not a new roof.

If the roof underneath is wet, failed, or structurally compromised, coating is the wrong scope — and we will say so. The service page for the work itself is commercial roof coatings.

How much does a commercial roof coating cost?

There is no honest one-price answer. The cost is driven by what the roof actually needs, not by a generic square-foot number.

What usually moves the price:

We price the work after we have seen the roof. We do not quote a coating from a photo or from roof size alone.

How long does a commercial roof coating last?

It depends on the chemistry, how thick it is applied, the climate, ponding, foot traffic, and whether the roof is maintained. We will not put a life expectancy on your roof until it has been inspected and a system has been specified.

When a project qualifies, the manufacturer warranty is the term we can actually document. Recoating later can be part of keeping a restored roof in service, but that decision should come from the roof’s condition, not from a calendar guess.

What is the difference between silicone and acrylic roof coating?

They are different chemistries, and they are not interchangeable.

Silicone is typically the better conversation on low-slope roofs that hold water. Acrylic elastomeric coatings are often used as reflective finish coats on roofs that drain well. The right choice also depends on the existing membrane, the slope, the climate, and whether solar will go on top.

dGEN specifies from the manufacturer’s guidelines for that substrate. We do not put the same product on every roof. The systems we install are described on the commercial roof coatings page.

Which coating is better if my roof has ponding water?

If water sits on the roof, say so up front. It changes the specification.

Silicone systems are generally the ones manufacturers position for resistance to ponding water. Acrylic is usually a poor fit where water regularly stands. Ponding is also a drainage issue, not only a product issue. The inspection should tell you whether the standing water can be addressed, and whether the roof is still a coating candidate at all.

Does a commercial roof coating come with a warranty?

Often yes, when the system is installed to the manufacturer’s requirements and the roof qualifies. Coverage, term, and conditions are set by the manufacturer. They are not a blanket promise.

Eligibility usually depends on the condition of the existing roof, the specified system, the required film thickness, and who applies it. We will tell you what warranty, if any, applies to your project before work begins. When the system qualifies, warranty documentation is part of closeout.

Will a coating void or affect my existing roof warranty?

It can. If the current roof is still under a manufacturer warranty, a coating applied without that manufacturer’s approval can put the existing coverage at risk. Ask the original manufacturer before anyone coats the roof.

If the existing warranty has already expired, that concern is smaller. The new system, when it qualifies, carries its own manufacturer warranty. Either way, this is a check that should happen before the work is specified, not after.

Why do you inspect and scan for moisture before coating?

Because a coating should not go over a wet roof. Wet insulation left in place can stay trapped under the new surface.

Before we coat, we survey the existing roof with an infrared moisture scan, mark wet or suspect areas, and repair or replace those areas so the coating goes on a dry, sound roof. We also test adhesion before the full system goes down.

Roof moisture scans and related thermal imaging surveys are led by Walt Jordan, Certified Infrared Thermographer®, No. 16631. The coating-project sequence is explained on the commercial roof coatings page, in the section “Due Diligence Before We Coat.” After hail or wind, a broader roof damage assessment may be the right first step.

Does a reflective coating help in Texas heat?

A white, reflective coating is designed to send solar heat away from the roof instead of soaking it in. In a Texas summer, that is often one of the reasons owners look at a coating: a cooler roof surface, less heat moving into the building, and less ultraviolet wear on the roof itself.

How much that matters on your building depends on the roof color and condition now, the specified coating, the insulation, and how the building is used. We will not attach a savings figure to a roof we have not seen. The inspection is what tells us whether a reflective coating is appropriate, and whether the roof can take it.

Is every commercial roof a candidate for a coating?

No. If the insulation is wet, the membrane is beyond restoration, or the structure needs work, replacement is the honest scope.

A coating is worth considering when the existing roof is still sound and the problems you have can be solved by restoring the surface. That is the point of the moisture scan and the adhesion test: to decide, not to justify a coating that should not be applied. If the roof needs to be replaced instead, see our commercial and industrial roofing work.

If you want a straight answer on your building, contact dGEN Energy Partners. The first step is a look at the roof, including a moisture scan when a coating is on the table.